Native Flags for IMPROVE RHR Metrics II, Annual Group Means
Here are your query results:
ProtocolIDFlagStatusFlagDescriptionFlagTypeSourceColumn
1004 V4UnknownTemporaryFLAG_%
10040M1Data points with NULL values in Debbie Miller's RHR data that have a '0' value in the flag_a, flag_b, flag_c, or flag_d field.Quality AssuranceFLAG_%
1004AAM2ORGANIC ARTIFACT CORRECTEDQuality AssuranceFLAG_%
1004APV5Possible Organic ArtifactQuality AssuranceFLAG_%
1004BIM2Incorrect installation of sample cartridge during weekly changeQuality AssuranceFLAG_%
1004CGV6Clogged Filter, generally associated with fire impact. The final flow rate is less than one-half of the initial flow rate.Quality AssuranceFLAG_%
1004CLM3Clogged Filter, generally associated with fire impact. The final flow rate is less than one-half of the initial flow rate.Quality AssuranceFLAG_%
1004DAM1Did not analyzeQuality AssuranceFLAG_%
1004DBNULLV4UnknownTemporaryFLAG_%
1004DEV2Derived valueQuality AssuranceFLAG_%
1004DFV4UnknownUnknownFLAG_%
1004EEV4Unknown flagTemporaryFLAG_%
1004EPM1Equipment ProblemQuality AssuranceFLAG_%
1004LCV0UnknownUnknownFLAG_%
1004LDV0Below detection limit - at one point this flag was mapped to 'NM'Quality AssuranceFLAG_%
1004LFV6The flow is greater than 10% higher or lower than the nominal flow rate. This effects the cut point of the particle but the concentrations are correct.Quality AssuranceFLAG_%
1004MMV4UnknownUnknownFLAG_%
1004NAM1Not Applicable. This is used for missing modules with non-protocol samplers with less than four modules.Quality AssuranceFLAG_%
1004NMV0NORMALQuality AssuranceFLAG_%
1004NRV0Samples that have OP=0 that may actually have a negative OP.Quality AssuranceFLAG_%
1004NSM1Operator did not install the samples or installed them too late to acquire a valid time. All filters involved.Quality AssuranceFLAG_%
1004OLM1Off Line. In some cases, this is used when the sampler is inoperable due to hurricane or fire. For year 2000, this is used for the period after the Version 1 sampler is removed and before the Version 2 samples begins operation.Quality AssuranceFLAG_%
1004PCV5Possible contaminationQuality Assuranceflag_<n>
1004POM1Power Outage. All filters involved.Quality AssuranceFLAG_%
1004QAI1QA problem suspected, value held back for further investigationQuality AssuranceFLAG_%
1004QCV4Valid value despite failing to meet some QC or statistical criteria.Quality AssuranceFLAG_%
1004QDV4Questionable dataQuality AssuranceFLAG_%
1004RFV6The flow is greater than 20% higher or lower than the nominal flow rate. This affects the cut point of the particle but the concentrations are correct.Quality AssuranceFLAG_%
1004SAV6Used to indicate some sort of 'Sampling Anomaly', though the exact definition has yet to be satisfactorily defined.Quality AssuranceFLAG_%
1004SDV6Short Duration Sample; The sample is too short for use in calculating RHR metrics, but it is still a meaningful result that is useful in other contexts.Quality AssuranceFLAG_%
1004SEV0UnknownUnknownFLAG_%
1004SOV4Sent OutTemporaryFLAG_%
1004SPV0An artifact filter was swapped with a sample filter.Quality AssuranceFLAG_%
1004SUVSA data value from another monitoring site or a modeled/estimated data value has been substituted for the original missing/invalid value.Quality AssuranceFLAG_%
1004SWV0Suspected filter swap.Quality AssuranceFLAG_%
1004TOV6Timing Outside normal boundsQuality AssuranceFlag_%
1004TUV6Non-standard sampling conditionsQuality AssuranceFLAG_%
1004UNM2The concentrations failed the data validation for unknown reasons. Quality AssuranceFLAG_%
1004XXM2The filter is damaged. Quality AssuranceFLAG_%