Native Flags for IMPROVE Aerosol, Regional Haze Rule III (2018 Guidance)
Here are your query results:
ProtocolIDFlagStatusFlagDescriptionFlagTypeSourceColumn
1006 V4UnknownTemporaryFLAG_%
10060M1Data points with NULL values in Debbie Miller's RHR data that have a '0' value in the flag_a, flag_b, flag_c, or flag_d field.Quality AssuranceFLAG_%
1006AAM2ORGANIC ARTIFACT CORRECTEDQuality AssuranceFLAG_%
1006APV5Possible Organic ArtifactQuality AssuranceFLAG_%
1006BIM2Incorrect installation of sample cartridge during weekly changeQuality AssuranceFLAG_%
1006CGV6Clogged Filter, generally associated with fire impact. The final flow rate is less than one-half of the initial flow rate.Quality AssuranceFLAG_%
1006CLM3Clogged Filter, generally associated with fire impact. The final flow rate is less than one-half of the initial flow rate.Quality AssuranceFLAG_%
1006DAM1Did not analyzeQuality AssuranceFLAG_%
1006DBNULLV4UnknownTemporaryFLAG_%
1006DEV2Derived valueQuality AssuranceFLAG_%
1006DFV4UnknownUnknownFLAG_%
1006EEV4Unknown flagTemporaryFLAG_%
1006EPM1Equipment ProblemQuality AssuranceFLAG_%
1006LCV0UnknownUnknownFLAG_%
1006LDV0Below detection limit - at one point this flag was mapped to 'NM'Quality AssuranceFLAG_%
1006LFV6The flow is greater than 10% higher or lower than the nominal flow rate. This effects the cut point of the particle but the concentrations are correct.Quality AssuranceFLAG_%
1006MMV4UnknownUnknownFLAG_%
1006NAM1Not Applicable. This is used for missing modules with non-protocol samplers with less than four modules.Quality AssuranceFLAG_%
1006NMV0NORMALQuality AssuranceFLAG_%
1006NRV0Samples that have OP=0 that may actually have a negative OP.Quality AssuranceFLAG_%
1006NSM1Operator did not install the samples or installed them too late to acquire a valid time. All filters involved.Quality AssuranceFLAG_%
1006OLM1Off Line. In some cases, this is used when the sampler is inoperable due to hurricane or fire. For year 2000, this is used for the period after the Version 1 sampler is removed and before the Version 2 samples begins operation.Quality AssuranceFLAG_%
1006PCV5Possible contaminationQuality Assuranceflag_<n>
1006POM1Power Outage. All filters involved.Quality AssuranceFLAG_%
1006QAI1QA problem suspected, value held back for further investigationQuality AssuranceFLAG_%
1006QCV4Valid value despite failing to meet some QC or statistical criteria.Quality AssuranceFLAG_%
1006QDV4Questionable dataQuality AssuranceFLAG_%
1006RFV6The flow is greater than 20% higher or lower than the nominal flow rate. This affects the cut point of the particle but the concentrations are correct.Quality AssuranceFLAG_%
1006SAV6Used to indicate some sort of 'Sampling Anomaly', though the exact definition has yet to be satisfactorily defined.Quality AssuranceFLAG_%
1006SDV6Short Duration Sample; The sample is too short for use in calculating RHR metrics, but it is still a meaningful result that is useful in other contexts.Quality AssuranceFLAG_%
1006SEV0UnknownUnknownFLAG_%
1006SOV4Sent OutTemporaryFLAG_%
1006SPV0An artifact filter was swapped with a sample filter.Quality AssuranceFLAG_%
1006SUVSA data value from another monitoring site or a modeled/estimated data value has been substituted for the original missing/invalid value.Quality AssuranceFLAG_%
1006SWV0Suspected filter swap.Quality AssuranceFLAG_%
1006TOV6Timing Outside normal boundsQuality AssuranceFlag_%
1006TUV6Non-standard sampling conditionsQuality AssuranceFLAG_%
1006UNM2The concentrations failed the data validation for unknown reasons. Quality AssuranceFLAG_%
1006XXM2The filter is damaged. Quality AssuranceFLAG_%