Site Details |
| Country: | United States |
| State: | Arizona (pop. 3665228) |
| County: | Gila County (pop. 40216) |
| Location2: | Next to maintenance building |
| Latitude: | 33.6548 |
| Longitude: | -111.1068 |
| Elevation: | 775m above MSL |
| EPA Code: | 040070010 |
| Agency: | US Forest Service |
| Sponsor: | NPS |
| Region: | Mogollon Plateau |
| Land Use: | Unknown |
| AQCR: | None |
| Dates: | 4/1988 - Present |
| SiteID: | 44 |
| SiteCode: | TONT1 |
| SiteName: | Tonto NM |
| Maps: | Google, MSN, Yahoo |
Site History |
| 12/25/1999: | offline until 02/16/2000 |
| 12/15/2004: | A1 Module hose to pump relaced |
| 12/15/2004: | B1 Module hose to pump relaced |
| 12/15/2004: | C1 Module hose to pump relaced |
| 12/15/2004: | D1 Module hose to pump relaced |
| 12/10/2004: | A1 Module Flow Calibration |
| 12/10/2004: | B1 Module Flow Calibration |
| 12/10/2004: | C1 Module Flow Calibration |
| 12/10/2004: | D1 Module Flow Calibration |
| 12/10/2004: | Routine annual maintenance |
| 12/10/2001: | A1 Module Flow Calibration |
| 12/10/2001: | B1 Module Flow Calibration |
| 12/10/2001: | C1 Module Flow Calibration |
| 12/10/2001: | D1 Module Flow Calibration |
| 12/09/1997: | D1 Module Flow Calibration |
| 11/24/1997: | C1 Module Flow Calibration |
| 11/22/1995: | Prescribed fire in area this week |
| 11/19/1997: | constuction nearby |
| 11/15/2004: | D1 Module electronics box replaced |
| 11/15/2004: | Sampler controller replaced |
| 11/15/1995: | Prescribed fire for last 10 days near monument |
| 11/12/1997: | Prescribed fire |
| 11/10/1999: | fire |
| 11/09/1996: | Heavy smoke in area from fire |
| 11/05/1997: | Prescribed fire and construction near sampler. |
| 10/29/1997: | Large prescribed fire |
| 10/27/1999: | Prescribed fire this week |
| 10/22/1997: | Prescribed fire |
| 10/20/1999: | Three prescribed fires in area for past week poor visibility |
| 10/15/1997: | Large prescribed fire |
| 10/11/2002: | road construction and prescribed fire |
| 10/01/1998: | A1 Module pump replaced |
| 10/01/1998: | B1 Module pump replaced |
| 10/01/1998: | C1 Module pump replaced |
| 10/01/1998: | Cyclones replaced |
| 10/01/1998: | D1 Module magnehelic replaced |
| 10/01/1998: | D1 Module pump replaced |
| 10/01/1998: | Denuder replaced |
| 10/01/1998: | Surge protector installed |
| 09/20/1995: | Prescribed fire 3 miles away from monument |
| 09/10/1997: | open ditch next to station |
| 09/06/2000: | A1 Module Flow Calibration |
| 09/06/2000: | B1 Module Flow Calibration |
| 09/06/2000: | C1 Module Flow Calibration |
| 09/06/2000: | D1 Module Flow Calibration |
| 09/05/2002: | road construction for the next year or so |
| 09/03/1998: | A1 Module Flow Calibration |
| 09/03/1998: | B1 Module Flow Calibration |
| 09/03/1998: | C1 Module Flow Calibration |
| 09/03/1998: | D1 Module Flow Calibration |
| 09/03/1998: | Routine annual maintenance |
| 09/02/2003: | Sampler controller replaced |
| 08/27/1997: | There's an excavation approx. 20 feet away from site |
| 08/14/2004: | D1 Module pump replaced |
| 08/13/2003: | building hit by lightening |
| 07/16/2004: | Sampler controller replaced |
| 07/10/1994: | A1 Module Flow Calibration |
| 07/10/1994: | B1 Module Flow Calibration |
| 07/10/1994: | C1 Module Flow Calibration |
| 07/10/1994: | D1 Module Flow Calibration |
| 07/10/1994: | Routine annual maintenance |
| 07/09/2004: | D1 Module pump replaced |
| 07/01/1995: | Two large fires occurring near the monument this week |
| 06/28/1994: | Changed nylon filter size from 47mm diameter to 25mm |
| 06/21/1995: | Prescribed fire in area |
| 06/19/2002: | smoke next two weeks |
| 06/14/1995: | 15 acre fire within 7 miles of monument |
| 06/06/1998: | 200 acre fire 2 miles from monument |
| 05/20/1998: | lots of smoke from Mexico fire |
| 05/17/1995: | A1 Module Flow Calibration |
| 05/17/1995: | B1 Module Flow Calibration |
| 05/17/1995: | C1 Module Flow Calibration |
| 05/17/1995: | D1 Module Flow Calibration |
| 05/17/1995: | Routine annual maintenance |
| 05/13/1998: | A1 Module Flow Calibration |
| 05/08/2002: | Sampler controller replaced |
| 05/08/1996: | still some smoke from Lone Fire hot spots |
| 05/01/1996: | fire, 61370 acres continues this week |
| 04/24/1996: | fire 8 miles W start 4/27. 15000+ acre. out of control by 4/29/96 |
| 04/21/2004: | A1 Module area increased from 2.20 to 3.53 sq cm |
| 04/03/2000: | Version 2 IMPROVE sampler installed |
| 04/03/2000: | A1 Module Flow Calibration |
| 04/03/2000: | B1 Module Flow Calibration |
| 04/03/2000: | C1 Module Flow Calibration |
| 04/03/2000: | D1 Module Flow Calibration |
| 04/03/2000: | Version 2 sampler installed |
| 04/03/1996: | Added glycerin to Module B1 denuder |
| 04/03/1996: | B1 Module Flow Calibration |
| 04/03/1996: | B1 Module pump replaced |
| 04/03/1996: | C1 Module Flow Calibration |
| 04/03/1996: | C1 Module pump replaced |
| 04/03/1996: | D1 Module Flow Calibration |
| 04/03/1996: | D1 Module magnehelic replaced |
| 04/03/1996: | D1 Module pump replaced |
| 04/03/1996: | Routine annual maintenance |
| 04/03/1996: | A1 Module Flow Calibration |
| 04/03/1996: | A1 Module pump replaced |
| 03/27/2004: | C1 Module electronics box replaced |
| 03/27/2004: | C1 Module Flow Calibration |
| 03/27/2004: | C1 Module pump replaced |
| 03/27/2004: | D1 Module electronics box replaced |
| 03/27/2004: | D1 Module Flow Calibration |
| 03/27/2004: | D1 Module pump replaced |
| 03/27/2004: | Photos taken |
| 03/27/2004: | Routine annual maintenance |
| 03/27/2004: | A1 Module electronics box replaced |
| 03/27/2004: | A1 Module Flow Calibration |
| 03/27/2004: | A1 Module motor replaced |
| 03/27/2004: | B1 Module electronics box replaced |
| 03/27/2004: | B1 Module Flow Calibration |
| 03/27/2004: | B1 Module pump replaced |
| 03/27/2003: | A1 Module Flow Calibration |
| 03/27/2003: | A1 Module pump replaced |
| 03/27/2003: | B1 Module Flow Calibration |
| 03/27/2003: | B1 Module pump replaced |
| 03/27/2003: | C1 Module Flow Calibration |
| 03/27/2003: | D1 Module Flow Calibration |
| 03/27/2003: | Photos taken |
| 03/27/2003: | Routine annual maintenance |
| 03/27/1994: | A1 Module Flow Calibration |
| 03/27/1994: | B1 Module Flow Calibration |
| 03/27/1994: | C1 Module Flow Calibration |
| 03/27/1994: | D1 Module Flow Calibration |
| 03/27/1994: | Routine annual maintenance |
| 03/25/2002: | A1 Module Flow Calibration |
| 03/25/2002: | A1 Module pump replaced |
| 03/25/2002: | B1 Module Flow Calibration |
| 03/25/2002: | B1 Module pump replaced |
| 03/25/2002: | C1 Module Flow Calibration |
| 03/25/2002: | D1 Module Flow Calibration |
| 03/25/2002: | Photos taken |
| 03/25/2002: | Routine annual maintenance |
| 03/25/1997: | A1 Module Flow Calibration |
| 03/25/1997: | B1 Module Flow Calibration |
| 03/25/1997: | C1 Module Flow Calibration |
| 03/25/1997: | D1 Module Flow Calibration |
| 03/25/1997: | Routine annual maintenance |
| 03/18/1998: | Open house over 1000 cars |
| 02/15/2000: | D1 Module pump replaced |
| 02/15/2000: | Sampler controller clock replaced |
| 02/14/1996: | Prescribed fire in area for over a week |
| 02/13/2002: | heavy construction next two weeks |
| 02/08/2004: | Sampler controller replaced |
| 01/28/2004: | A1 Module pump replaced |